GAS REQUIREMENTS
Verify the type of gas supplied to the location. The cooktop is shipped from the factory set up and adjusted for
Natural Gas or LP (propane), depending on the specific model ordered.
Verify that the cooktop is compatible
with gas supply at the installation site before proceeding further.
Return the cooktop to the dealer if the unit is
not set for the gas supplied at the site.
NATURAL GAS
Connection: 1/2” NPT Minimum 5/8” dia. flex line. Supply Pressure: 6” to 9” W.C.
LP GAS
Connection: 1/2” NPT Minimum 5/8 dia. flex line. Supply Pressure: 11” to 14” W.C.
A regulator is required at the LP source to provide a maximum of 14” W.C. to the cooktop regulator.
HOOKUP TO GAS SUPPLY
A manual valve must be installed external to the appliance, in an
accessible location from the front for the purpose of shutting off the gas
supply (Fig. 9). Make sure the gas supply is turned off at the wall valve
before connecting the appliance. The gas supply connections should
be made by a qualified technician and in accordance with local codes
or ordinances. In the absence of a local code, the installation must
conform to the latest edition of National Fuel Gas Code ANSI Z223.1.
To prepare the unit for connection to the gas supply, thread the
supplied 1/2” pipe nipple into the elbow on the end of the manifold.
The elbow is located inside the chassis of the unit, on the end of the
manifold, facing down. See fig.10. It is accessible through the square
cutout in the left rear corner of the chassis bottom. Connect the outlet
of the regulator to the exposed end of the nipple, connect the flex line
from the gas supply to the inlet side of the regulator.
NOTE:
Pipe sealant must be used on all pipe threads.
CAUTION:
Leak-testing of the appliance shall be conducted
according to the manufacturer’s instructions. See
instructions in section ‘Test and adjustments’.
The appliance must be isolated from the building’s
gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less
than 1/2 psig (3.5kPa.).
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of the system at the test pressures in
excess of 1/2 psig (3.5kPa.).
When checking the manifold gas pressure, the inlet
pressure to the regulator should be at least 7.0 W.C. for
natural gas or 12.0 for LP.
NOTE:
The arrow on the regulator indicating direction of gas flow
should be pointing towards the unit. The flex line for the gas supply
must be metal and be approved by an approved certifying agency
(AGA, CGA, or UL). Never use a hose made of rubber or other synthetic
material, as the heat may cause the hose to melt and develop leaks.
GAS HOOKUP
Fig. 10
*Installation must conform with
local codes or with the National
Fuel Gas Code ANSI Z223.1 or
the CAN/CGA-B149.2 Propane
Installation Code
Coupling
1/2 NPT black
1/2 NPT
Close Nipple
Regulator
LP/NG (included)
Adapter 1/2 NPT
to 3/8aretting
Do not put threading
compound
on these
threads
Bottom of unit
Threading compound
must be resistant to LP gas
1/2 x 5" NPT
Close
Nipple
Installer supplied shut-o
valve must be easily
accessible*
Fig. 9
Flex Line to Cooktop
!